Medical Consumables and Lab Consumables OEM Manufacturer
Medical Consumables and Lab Consumables OEM Manufacturer

Host Cell Protein Residual Detection Kit for 293T

Product Name:293T HCP ELISA Detection Kit

This kit is designed for the quantitative detection of HCP (host cell protein) content in biopharmaceuticals expressed on 293T cells by using a double-antibody sandwich method.


This kit can be used to detect all components of HCP (host cell protein) in 293T cell.


Contact
Get A Quote
SKU: HG-HCP001
5

Features of Host Cell Protein Residual Detection Kit for 293T

High-Precision

37-27,000 ng/mL range - Broad detection capability

37 ng/mL sensitivity - Detect trace contaminants

<10% CV precision - Reliable reproducibility

Pre-coated plates - Consistent results


Optimized Workflow

Ready-to-use components - Save preparation time

90-minute incubation - Faster than competitors

Clear visual protocol - Minimize operator errors

<3 hour total time - Streamline QC process


Regulatory-Compliant

NIBSC/WHO aligned - Meet global standards

Full 293T coverage - No missed HCPs

10+ IND approved - Proven track record

8-month shelf life - Long-term reliability


General Workflow

1.Sample Preparation & Sample Addition

2.Incubation & Washing

3.Enzyme Conjugate & Final Washing

4.Color Development & Termination

5.Plate Reading & Analysis

Total Assay Time: Approximately 3.5 hours (including 30 minute equilibration)


Service Details

CategorySpecifications
Intended UseQuantitative detection of 293T host cell proteins (HCPs) in biopharmaceuticals using a double-antibody sandwich ELISA. For research use only.
Key FeaturesHigh sensitivity: Detection range 37–27,000 ng/mL; LOQ 37 ng/mL
Precision: CV ≤10%, RE ≤±15%
Broad compatibility: Detects all 293T HCP components
Ready-to-use: Pre-coated plates, TMB substrate included.
Kit Components- 293T HCP Coated Plate (96 wells)
- Anti-293T HCP-Biotin (150 μL)
- Streptavidin HRP (375 μL × 3)
- 293T HCP Standard (81 μg/mL)
- Diluent Buffer, PBS-T Wash Buffer, TMB Substrate, Stop Solution.
Storage & Shelf Life8 months at 2–8°C (protected from light).
Equipment Required- Microplate reader (450 nm)
- Thermostat plate shaker
- Pipettes & tips
- Deionized water.
Workflow1. Sample Prep: Dilute standards/samples with Diluent Buffer
2. Incubation: 1.5 h room temperature
3. Detection: Biotinylated antibody → HRP conjugate → TMB color development (15 min)
4. Readout: OD450 nm.
Data Analysis4-parameter curve fitting for quantification (example standard curve provided).
Turnaround Time3–4 hours (including incubation and development).
Advantages vs. CompetitorsHigher sensitivity: Lower LOQ (37 ng/mL) vs. typical 50 ng/mL kits
Optimized reagents: Pre-diluted standards reduce pipetting errors
Comprehensive QC: Includes CV/RE validation data.


Service Features

Solution 1: High-Sensitivity 293T HCP Quantification
Solution 2: Streamlined Workflow for GMP Compliance
Solution 3: Robust Performance for Complex Samples

Purpose: Accurately detect residual host cell proteins (37-27,000 ng/mL) in 293T cell-derived biologics to ensure product purity and safety.

Feature:Double-antibody sandwich ELISA with pre-coated 293T-specific antibodies for superior specificity (<10% CV)

Biotin-streptavidin HRP amplification enhances sensitivity (LOQ: 37 ng/mL) versus conventional kits

Application: Critical for QC of viral vectors, recombinant proteins, and gene therapies produced in 293T cells

Technical Effort:

Validated with 8-point standard curve (4-parameter fitting, R²>0.99) and precision (RE%≤±15%)

Includes ready-to-use TMB substrate for consistent 15-min color development


Purpose: Simplify HCP testing with minimal hands-on time while meeting regulatory requirements

Feature:Pre-coated 96-well strips reduce prep time; 3.5-hour total protocol (vs. 5+ hours for competitor kits)

Pre-formulated diluents (1×PBS-T) eliminate buffer preparation errors

Application: Ideal for lot-release testing in biopharmaceutical manufacturing (e.g., AAV, lentiviral vectors)

Technical Effort:

Optimized wash steps (3×250 μL PBS-T) minimize background noise

Room-temperature incubation (18-25°C) eliminates need for precise thermal control


Purpose: Overcome matrix interference in crude supernatants and purified biologics

Feature:Broad dynamic range (37-27,000 ng/mL) accommodates both upstream and downstream samples

Included dilution buffer stabilizes HCPs and prevents false negatives

Application: Suitable for process development, in-process testing, and final product validation

Technical Effort:

Validated spike recovery (85-115%) in cell lysates and culture media

Stable 8-month shelf life at 2-8°C with light protection



Case Studies

Case Studies 1: Bioprocess Monitoring for Viral Vector Manufacturing

Purpose: To quantify residual 293T host cell proteins in lentiviral vector batches for GMP compliance.

Feature:Broad detection range (37-27,000 ng/mL) eliminates need for sample dilution

Ready-to-use pre-coated plates save 50% hands-on time compared to traditional ELISA

Application:

Critical quality control for CAR-T cell therapy production

Validated for use with both crude supernatants and purified viral vectors

Technical Effort:

Cross-validated with mass spectrometry (R²=0.96)

Demonstrated ≤10% CV across multiple operators and instruments


Case Studies 2: Sensitivity Validation for Gene Therapy Products

Purpose: To detect low-level HCP contamination in AAV preparations.

Feature:Superior sensitivity (LOQ 37 ng/mL) outperforms commercial alternativesBiotin-streptavidin amplification enhances detection of trace HCPs

Application:

Identified HCP carryover differences between purification methods

Essential for process development and optimization

Technical Effort:

Validation against Western blot showed 100% concordance

Demonstrated <15% inter-assay variability in 20 consecutive runs


Case Studies 3: Specificity Testing for Biosimilar Development

Purpose: To confirm antibody specificity for 293T HCPs without cross-reactivity.

Feature:293T-specific antibodies show <0.1% cross-reactivity

Simplified sample preparation protocol (15 minutes)

Application:

Supports regulatory filings for biosimilar development

Used for process comparability studies

Technical Effort:

Comparative testing showed 20% higher sensitivity than commercial kits

4PL curve fitting achieved R²>0.99 with automated readers


Specification of 293T HCP ELISA Detection Kit


Specification96 Test

Assay range

37-27000ng/mL

Limit of quantitation

37ng/mL

Precision

CV%≤10%, RE%≤±15%

Validity period12  months
Storage conditions4℃
LOQ37 ng/mL
LOD30 ng/mL

Datasheet of 293T HCP ELISA Detection Kit

Concentration of standard(ng/mL)OD value 1OD value 2Mean value
270002.5072.4942.5005
90001.6181.6251.6215
30001.1761.1811.1785
10000.7730.770.7715
3330.4960.4750.4855
1110.2890.2850.287
370.2050.1950.2
00.140.1370.1385


Standard curve:

Datasheet of 293T HCP ELISA Detection Kit

Products
More
Bring your cellular therapy products to the next milestone sooner
Contact Us
Contact
86 198 5711 6962 info@hillgene.com
Avenue Building 4, Yuewang Wisdom Valley, 1463 Wuzhong Avenue, Wuzhong District, Suzhou China
Ask Us Anything!